Measurement Items
- CO, HC, CO₂, O₂, NOx, Lambda(λ), AFR, RPM, Oil Temp.
HC 0~15,000ppm
CO Correction Function
Measurement principle
- CO, HC, CO₂ : Non-Dispersive Infrared(NDIR)
- O₂, NOx : Electrochemical
Measuring range / Resolution function
- CO : 9.99% / 0.01%
- HC : 9999ppm / 1ppm
- CO₂ : 20.0% / 0.1%
- O₂ : 25.00% / 0.01%
- λ : 2.000 / 0.001
- AFR : 99.0 / 0.1
- NOx : 5000ppm / 1ppm
* Blue part is optional
Spec ▶ KS200-5G
Repeatability - under 2% FS
Response time - Max 10 sec(over 90%)
Preheating time - 5~6 minutes
Sampling volume - 4L/min
Voltage - 100~240V Free Voltage 50/60Hz
Temperature - 10℃~40℃
Size - 245(W) x 380(D) x 155(H)mm
Weight - About 6kg
Output Method - RS232
Spec ▶ KS200-5G(B)
Please refer to the KS200-5G
Power - Rechargeable 12V Li-ion Battery
Charging Method - 12V Adapter
Option