• NDIR technology for reliable
  • Convenient key operating system
  • Built-In Printer(Optional) / PC Program
  • KS200-2G(B)
    : Rechargeable lithium ion battery power.
    (Can operated along 5 hours continuously)

Measurement Items

- CO, HC

  HC 0~15,000ppm

Measurement principle

- CO, HC : Non-Dispersive Infrared(NDIR)

Measuring range / Resolution function

- CO : 9.99% / 0.01%

- HC : 9999ppm / 1ppm

* Blue part is optional

Spec โ–ถ KS200-2G

Repeatability - under 2% FS

Response time - Max 10 sec(over 90%)

Preheating time - 5~6 minutes

Sampling volume - 4L/min

Voltage - 100~240V Free Voltage 50/60Hz

Temperature - 10โ„ƒ~40โ„ƒ 

Size - 245(W) x 380(D) x 155(H)mm

Weight - About 6kg

Output Method - RS232


Spec โ–ถ KS200-2G(B)

Please refer to the KS200-2G

Power - Rechargeable 12V Li-ion Battery

Charging Method - 12V Adapter


Option

  • Built in Printer
  • HC 0~15,000ppm Range